International building code 2018 ibc 2018.
Minimum attic access size ibc.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
These specs are per r807 1 of the international residential code irc and the residential edition of the florida building code fbc.
Clear headroom of not less than 30 inches 762 mm shall be provided in the attic space at or above the access opening.
762 mm shall be provided in the attic space at or above the access opening.
Or is a step ladder code compliant.
Where wood shingles or shakes are used a minimum 1 4 inch.
From the finished floor to the ceiling shall not be included in any computation of the minimum area thereof.
Access to mechanical appliances installed in under floor areas.
International building code 2015 ibc 2015.
306 3 appliances in attics.
However is a permanent means of access required as in a fixed ladder.
Minimum opening size the 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
The rough framed opening must be a minimum of 22 inches by 30 inches.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Access 1 everyattic or roof space shall be provided with an access hatch where the attic or roof space a measures not less than i 10 m in area ii 1 000 mm in length or width and iii 600 mm in height over at least the area described in subclauses i and ii or.
According to the 2006 international residential code r807 1 attic access homes with combustible materials in the ceiling and roof construction must have an access to attic areas that exceeds 30 square feet and with a vertical height of 30 inches or greater.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
Thanks from the 2009 imc.
2009 ibc from previous discussions i understand that stairs are not required to attics.